Publications

Results 1–25 of 30
Skip to search filters

Assessment of Physics Models for Phase Transition Kinetics

Kalita, Patricia K.

The time dependence of phase diagrams and how to model rate dependent transitions remains one of the key unanswered questions in physics. When a material is loaded dynamically through equilibrium phase boundaries, it is the kinetics that determines the real time expression of a phase transition. Here we report the atomic and nanosecond-scale quantification of kinetics of shock-driven phase transition in multiple materials. We uniquely make use of a both a simple shock as well as shock-and-hold loading pathways compress different crystalline solids and induce structural phase transitions below melt. Coupling shock loading with time-resolved synchrotron x-ray diffraction (DXRD), we probe the structural transformations of these solids in the short-lived high pressure and temperature states generated. The novelty and power of using DXRD for the assessment of kinetics of phase transitions lies in the ability to discover and identify new phases and to examine kinetics without prior knowledge of a material's phase diagram. Our results provide a quantified expression and a physics model of kinetics of formation of high-pressure phases under shock loading: transition incubation time, evolution, completion time and crystallization rate.

More Details

A Platform-Independent X-ray Diffraction Diagnostic for Phase Transition Kinetics in Traditional and Synthetic Microstructure Materials (LDRD Project 213088 Final Report)

Ao, Tommy A.; Austin, Kevin N.; Breden, E.W.; Brown, Justin L.; Dean, Steven W.; Duwal, Sakun D.; Fan, Hongyou F.; Kalita, Patricia K.; Knudson, Marcus D.; Meng, Lingyao M.; Morgan, Dane D.; Pacheco, Lena M.; Qin, Yang Q.; Stoltzfus, Brian S.; Thurston, Bryce A.; Usher, Joshua M.; Lane, James M.

Pulsed-power generators using the magnetic loading technique are able to produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength-strain rate dependence, structural phase transitions, and density of crystal defects such as dislocations. Here, we present a cost effective, compact X-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically-driven ramp compression of materials with single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials community. The success in fielding this new XRD diagnostic dramatically improves our predictive capability and understanding of rate-dependent behavior at or near phase transition. As Sandia plans the next-generation pulse-power driver platform, a key element needed to deliver new state-of-the-art experiments will be having the necessary diagnostic tools to probe new regimes and phenomena. These diagnostics need to be as versatile, compact, and portable as they are powerful. The development of a platform-independent XRD diagnostic gives Sandia researchers a new window to study the microstructure and phase dynamics of materials under load. This project has paved the way for phase transition research in a variety of materials with mission interest.

More Details

Dynamic x-ray diffraction and nanosecond quantification of kinetics of formation of β -zirconium under shock compression

Physical Review B

Kalita, Patricia K.; Brown, Justin L.; Specht, Paul E.; Root, Seth R.; White, Melanie; Smith, Jesse S.

We report the atomic- and nanosecond-scale quantification of kinetics of a shock-driven phase transition in Zr metal. We uniquely make use of a multiple shock-and-release loading pathway to shock Zr into the β phase and to create a quasisteady pressure and temperature state shortly after. Coupling shock loading with in situ time-resolved synchrotron x-ray diffraction, we probe the structural transformation of Zr in the steady state. Our results provide a quantified expression of kinetics of formation of β-Zr phase under shock loading: transition incubation time, completion time, and crystallization rate.

More Details

A spherical crystal diffraction imager for Sandia’s Z Pulsed Power Facility

Review of Scientific Instruments

Ao, Tommy A.; Schollmeier, Marius; Kalita, Patricia K.; Gard, Paul D.; Smith, Ian C.; Shores, Jonathon S.; Speas, Christopher S.; Seagle, Christopher T.

Sandia’s Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigating fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Material Property (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect a diffraction signal close to the Z-DMP load and to recover the data. We have developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn–Heα x rays to probe a shock-compressed material on the Z-DMP load. Finally, a spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x rays into a 1-in. thick tungsten housing, where an image plate is used to record the data.

More Details

X-ray diffraction of dynamically compressed matter on Sandia?s Z Pulsed Power Facility

Ao, Tommy A.; Schollmeier, Marius; Kalita, Patricia K.; Gard, Paul D.; Williams, James R.; Blada, Caroline B.; Hanshaw, Heath L.; Smith, Ian C.; Shores, Jonathon S.; Speas, Christopher S.; Seagle, Christopher T.

Sandia's Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigations of fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice, and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Materials Properties (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect the XRD pattern close to the Z-DMP load and to recover the data. We developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn-He c , x-rays to probe a shock-compressed sample on the Z-DMP load. A spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x-rays into a 1-inch thick tungsten housing, where an image plate is used to record the data. We performed experiments to implement the SCDI diagnostic on Z to measure the XRD pattern of shock compressed beryllium samples at pressures of 1.8-2.2 Mbar.

More Details

Polycapillary x-ray lenses for single-shot, laser-driven powder diffraction

Review of Scientific Instruments

Schollmeier, Marius; Ao, Tommy A.; Field, Ella S.; Galloway, B.R.; Kalita, Patricia K.; Kimmel, Mark W.; Morgan, D.V.; Rambo, Patrick K.; Schwarz, Jens S.; Shores, J.E.; Smith, Ian C.; Speas, C.S.; Benage, John F.; Porter, John L.

X-ray diffraction measurements to characterize phase transitions of dynamically compressed high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

More Details

X-Ray Diffraction Measurements on Laser-Compressed Polycrystalline Samples Using a Short-Pulse Laser Generated X-Ray Source

Schollmeier, Marius; Ao, Tommy A.; Field, Ella S.; Galloway, B.R.; Kalita, Patricia K.; Kimmel, Mark W.; Long, Joel L.; Morgan, Dane D.; Rambo, Patrick K.; Schwarz, Jens S.; Seagle, Christopher T.

Existing models for most materials do not describe phase transformations and associated lattice dy- namics (kinetics) under extreme conditions of pressure and temperature. Dynamic x-ray diffraction (DXRD) allows material investigations in situ on an atomic scale due to the correlation between solid-state structures and their associated diffraction patterns. In this LDRD project we have devel- oped a nanosecond laser-compression and picosecond-to-nanosecond x-ray diffraction platform for dynamically-compressed material studies. A new target chamber in the Target Bay in building 983 was commissioned for the ns, kJ Z-Beamlet laser (ZBL) and the 0.1 ns, 250 J Z-Petawatt (ZPW) laser systems, which were used to create 8-16 keV plasma x-ray sources from thin metal foils. The 5 ns, 15 J Chaco laser system was converted to a high-energy laser shock driver to load material samples to GPa stresses. Since laser-to-x-ray energy conversion efficiency above 10 keV is low, we employed polycapillary x-ray lenses for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. Polycapillary lenses enabled diffraction measurements up to 16 keV with ZBL as well as diffraction experiments with ZPW. This x-ray diffraction platform supports experiments that are complementary to gas guns and the Z facility due to different strain rates. Ultimately, there is now a foundation to evaluate DXRD techniques and detectors in-house before transferring the technology to Z. This page intentionally left blank.

More Details
Results 1–25 of 30
Results 1–25 of 30