7.6.18.12.32. Volume_Average

Syntax

Thermal Conductivity [{of} SpeciesName] = Volume_Average ()

Scope

Aria Material

Summary

Thermal conductivity computed from volume average of species thermal conductivities.

Description

k = \frac{ \sum_{i \in \text{species}} \left[\text{clip}(X_i) k_i\right]}{\sum_{i \in \text{species}} \text{clip}(X_i)}

where X_i is the volume fraction of species i, k_i the conductivity of species i and the \text{clip}() function clips values to the bounds [0, 1].

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string