7.6.8.3.14. Thermoelectric

Syntax

Heat Conduction [{of} SpeciesName] = Thermoelectric ()

Scope

Aria Material

Summary

Thermoelectric model for heat conduction

Description

Heat conduction is calculated as

{\bf{q}} = -k \nabla T +  SJT

where k is the heat conduction, T is temperature, S is the Seeback coefficient, and J is the current density. The Seeback coefficient must be defined in the material.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string