Cht_Flux

Syntax

Bc No_Coverage_Flux For Energy ([{of} SpeciesName] | [{in} MaterialPhaseName] | [{ls} {a | b | c}]) {@ | at | for | on | over} Mesh Extent Name ([Touching TouchingMeshExtent] | [Opposing OpposingMeshExtent]) = Cht_Flux [Using Data Specification Data Spec Name] ([Power_Output = power_output] | [Flux_Output = flux_output] | [Toggle = toggle] | [Too_Field = Too_Field] | [H_Field = H_Field])

Summary

Applies H(T-Too) flux for conjugate heat transfer boundary. Optional parameters are “Too_Field” and “H_Field”, which default to “nodal_cht_Too” and “nodal_cht_H” respectively.

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Power_Output

If specified, the total (integrated) power of the given BC/Src is calculated and stored into the global variable name specified as the power_output argument.

Flux_Output

If specified, the average flux of the given BC/Src is calculated and stored into the global variable name specified as the flux_output argument.

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

power_output

“string”

flux_output

“string”

toggle

“string”

Too_Field

“string”

nodal_cht_Too

H_Field

“string”

nodal_cht_H