Constant_With_Cutoff_Voltage

Syntax

Bc Flux For Current ([{of} SpeciesName] | [{in} MaterialPhaseName] | [{ls} {a | b | c}]) {@ | at | for | on | over} Mesh Extent Name ([Touching TouchingMeshExtent] | [Opposing OpposingMeshExtent]) = Constant_With_Cutoff_Voltage [Using Data Specification Data Spec Name] ([Toggle = toggle] | Value = value | Cutoff_Value = cutoff_value)

Summary

Apply a constant current until a cutoff voltage is crossed anywhere on the surface. After that apply 0 current.

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

toggle

“string”

value

real

cutoff_value

real