Conductance

Syntax

Bc Bulknode_Flux For Cvfem_Energy ([{of} SpeciesName] | [{in} MaterialPhaseName] | [{ls} {a | b | c}]) {@ | at | for | on | over} Mesh Extent Name ([Touching TouchingMeshExtent] | [Opposing OpposingMeshExtent]) = Conductance [Using Data Specification Data Spec Name] ([Bulk_Node = bulk_node] | [Toggle = toggle])

Summary

Applies a contact heat flux of the form C (T_{1} - T_{2}) to sides 1 and 2 of the contact interface where C is a user specified conductance coefficient. Used in conjunction with a CONDUCTANCE COEFFICIENT model.

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

bulk_node

“string”

toggle

“string”