7.13.1.8.26. User_Field

Syntax

Bc Dirichlet For Dof Name [{of} SpeciesName | {in} MaterialPhaseName | {ls} {a | b | c}] {on} Mesh Extent Name [Touching TouchingMeshExtent | Opposing OpposingMeshExtent] = User_Field [Using Data Specification Data Spec Name] [Power_Output = power_output | Flux_Output = flux_output | Toggle = toggle | Name = name | Scaling = scaling | Global_Var = global_var | Time_Function = time_function]

Summary

Value from a user field

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Power_Output

If specified, the total (integrated) power of the given BC/Src is calculated and stored into the global variable name specified as the power_output argument.

Flux_Output

If specified, the average flux of the given BC/Src is calculated and stored into the global variable name specified as the flux_output argument.

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

Dof Name

string

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

{on}

{@ | at | for | in | on | over}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

power_output

“string”

flux_output

“string”

toggle

“string”

name

“string”

scaling

real

1

global_var

“string”

time_function

“string”