Resistive_Load
- Syntax
Bc Lumped_Flux For Current [ SpeciesName | MaterialPhaseName | ] Mesh Extent Name [Touching TouchingMeshExtent | Opposing OpposingMeshExtent] = Resistive_Load [Using Data Specification Data Spec Name] [Toggle = toggle | Area = Area | Referencevoltage = ReferenceVoltage]
- Summary
Model a boundary attached to a resistive load. The local applied current density is V / (R A) where V is the local voltage, R is the specified resistance, and A is the area of the surface the BC is applied to.
- Description
The following options are present in most boundary conditions/sources. The meaning of each option is as follows:
- Toggle
If given, specifies which toggle block controls whether this BC is active or not.
Parameter |
Value |
Default |
|---|---|---|
{of | species | subindex} |
– |
|
SpeciesName |
string |
– |
{in | material_phase} |
– |
|
MaterialPhaseName |
string |
– |
{levelset_phase | ls} |
– |
|
{@ | at | for | in | on | over} |
– |
|
Mesh Extent Name |
string |
– |
TouchingMeshExtent |
string |
– |
OpposingMeshExtent |
string |
– |
Data Spec Name |
string |
– |
toggle |
“string” |
– |
Area |
real |
-1 |
ReferenceVoltage |
real |
0 |