Butler_Volmer

Syntax

Bc Interface For Current [{of} SpeciesName | {in} MaterialPhaseName | {ls} {a | b | c}] {on} Mesh Extent Name [Touching TouchingMeshExtent | Opposing OpposingMeshExtent] = Butler_Volmer [Using Data Specification Data Spec Name] [Toggle = toggle | F = f | R = r | Alpha_A = alpha_a | Alpha_C = alpha_c | Flux_Lim_A = flux_lim_a | Flux_Lim_C = flux_lim_c | Sign = sign | Use_Solid_Stress = use_solid_stress | Use_Liquid_Stress = use_liquid_stress | Trans = trans | Reaction_Name = reaction_name]

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

{on}

{@ | at | for | in | on | over}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

toggle

“string”

f

real

r

real

alpha_a

real

alpha_c

real

flux_lim_a

real

0

flux_lim_c

real

0

sign

integer

use_solid_stress

“string”

use_liquid_stress

“string”

trans

real

0.3

reaction_name

“string”