Resistive_Load

Syntax

Bc Flux For Current [{of} SpeciesName | {in} MaterialPhaseName | {ls} {a | b | c}] {on} Mesh Extent Name [Touching TouchingMeshExtent | Opposing OpposingMeshExtent] = Resistive_Load [Using Data Specification Data Spec Name] [Toggle = toggle | Area = Area | Referencevoltage = ReferenceVoltage]

Summary

Model a boundary attached to a resistive load. The local applied current density is V / (R A) where V is the local voltage, R is the specified resistance, and A is the area of the surface the BC is applied to.

Description

The following options are present in most boundary conditions/sources. The meaning of each option is as follows:

Toggle

If given, specifies which toggle block controls whether this BC is active or not.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

{in}

{in | material_phase}

MaterialPhaseName

string

{ls}

{levelset_phase | ls}

{on}

{@ | at | for | in | on | over}

Mesh Extent Name

string

TouchingMeshExtent

string

OpposingMeshExtent

string

Data Spec Name

string

toggle

“string”

Area

real

-1

ReferenceVoltage

real

0