7.6.18.12.24. Saturation_Power_Law

Syntax

Thermal Conductivity [{of} SpeciesName] = Saturation_Power_Law [K_Dry = k_dry | K_Wet = k_wet | Power = power]

Scope

Aria Material

Summary

Thermal conductivity as a power law in liquid saturation for two phase porous flows.

Description

k =

\begin{cases}
    k_\text{dry} + S_l^p (k_\text{wet} - k_\text{dry}), & S_l > 1e-4 \\
    k_\text{dry}, & s_l <= 1e-4
  \end{cases}

where S_l is the liquid saturation, and p the provided “power” parameter.

The provided “power” may not be zero, and at least one of “k_dry” and “k_wet” must be non-zero.

Parameter

Value

Default

{of}

{of | species | subindex}

SpeciesName

string

k_dry

real

k_wet

real

power

real