Description of Gas-Phase Data (CHEMKIN) Format
The input format for the CHEMKIN application consists of four 80-character
text records, numbered 1 thru 4 in column 80.
In addition to the fourteen (14) fit coefficients, the input also contains
the species' name, its elemental composition, computational temperature limits,
and an indication of its phase (gas, liquid, or solid).
Note: Spaces have been added to the example below for readability.
|
These fits can be used with the CHEMKIN software package and are defined by:
Cp(T) / R = a1
+ a2T
+ a3T 2
+ a4T 3
+ a5T 4
H°(T) |
= |
a1 |
+ |
a2 |
T |
+ |
a3 |
T 2 |
+ |
a4 |
T 3 |
+ |
a5 |
T 4 |
+ |
a6 |
 |
 |
 |
 |
 |
 |
| RT |
2 |
3 |
4 |
5 |
T |
| S°(T) |
= |
a1
ln(T ) |
+ |
a2T |
+ |
a3 |
T 2 |
+ |
a4 |
T 3 |
+ |
a5 |
T 4 |
+ |
a7 |
 |
 |
 |
 |
| R |
2 |
3 |
4 |
where
T is temperature (K),
Cp(T) is heat capacity (kcal/mol-K) at temperature T,
H°(T) is enthalpy (kcal/mol) at temperature T,
S°(T) is entropy (kcal/mol-K) at temperature T, and
R = 0.001987 kcal/mol-K
Note that
H°(T) = H°(T) - H°(298) + Hf°(298),
where Hf°(298)
is the species heat of formation at 298K, H°(T)
is the standard enthalpy at temperature T, and H°(298)
is the standard enthalpy at 298K.
Fits were carried out over two separate temperature ranges.
The low, high, and break temperatures for these two fits
are given at the end of the first line of the thermo data.
For example, for the species BCl, the data were fit over
the ranges 300 - 1000K and 1000 - 3000K. (Also see example
above.)
The subsequent three lines of numbers in the data record
are the fitting parameters a1 - a7 for each fit.
The parameters for the high-temperature range are given first,
followed by those for the low-temperature range.
More information concerning this format can be found
in the Chemkin III manual.
|
|